Projector Starts then Shuts Down (Lamp Units)
- Check lamp hours; fit a known‑good lamp if near EOL.
- Clean filters/vents; ensure fans reach target RPM.
- Verify door‑switch/interlocks are engaged.
- Scope ballast ignition; if misfiring, service/replace.
Welcome to the Wells Electronics knowledge base for BenQ projectors. Here you will find troubleshooting guides, error code explanations, maintenance tips, and downloadable manuals to help you get the best from your projector.
Book a Free CollectionQuick, practical guides for common BenQ projector issues. Use search or category filters, or browse the featured articles.
Lamp strikes, dim image, colour wheel timing, ballast faults.
Light source errors, derating, optical engine cleanliness.
Android TV crashes, HDMI handshakes, LED drivers.
Progressive white dots are almost always a failing DMD chip. Cleaning won’t remove fixed dots.
Likely a tach feedback or fan controller IC issue. The fans move air, but the RPM signal fails validation.
Fine dust on mirrors/prisms lowers contrast and adds a mild colour cast.
Likely a fan controller IC or tach feedback issue. The fans move air but RPM isn’t validated. Controller/board service usually resolves it.
Check that the lamp is genuine and seated. Verify colour wheel timing and clean the optics/filters. Measure ballast outputs if strike takes multiple attempts.
Monthly in dusty spaces, quarterly otherwise. Record brightness and noise levels to catch slow fan failures early.
Describe the symptoms and we’ll triage it remotely. If needed, we’ll arrange free collection & return.